Power at Pickup Alternating Current (AC) Voltage (Typical)

6.9 V·A

Contacts

Arrangement

Double Pole Single Throw (DPST) ( 2 Form A and B ) Single Pole Double Throw (SPDT) ( 1 Form C), DPDT ( 2 Form C) Single Pole Single Throw (SPST) ( 1 Form A and B), Single Pole Single Throw (SPST)-NO-DM ( Form 1X) Single Pole Single Throw (SPST)-NC-DB (Form 1Y)

Maximum Switched Power Resistive Load Rating

840 W12000 V·A

Maximum Switched Current Resistive Load Rating

30 A

Maximum Switched Direct Current (DC) Voltage Resistive Load Rating

28 V

Maximum Switched Alternating Current (AC) Voltage Resistive Load Rating

600 V

Rated Load Current (Underwriter Laboratories (UL))

30 A at 240 VAC Res. [PRDQ series][PRDS][PRDD]
1.5 HP at 120; 240 VAC [PRDQ series][PRDS][PRDD]
2.0 HP at 240; 277; 600 VAC [PRDQ series][PRDS][PRDD]
3600 W at 120 VAC / 240 VAC ballast [PRDQ series][PRDS][PRDD]
30 A at 240 VAC Res., 100k cycles [PRDQ series][PRDS][PRDD]
20 A at 600 VAC Res. [PRDQ series][PRDS][PRDD]
30 A at 28 VDC Res.[PRDQ series][PRDS][PRDD]
Aux. Snap Switch 1/4 HP at 125 VAC / 240 VAC [PRDS]
20 A at 125 VDC [PRDD]
50 A at 277 VAC Res., [PRDE][PRDR]
40 A at 277 VAC General use (inductive) [PRDE][PRDR]

Material

Silver Cadmium Oxide

Initially Resistance1 < 50 mΩ

General Data

Mechanical Life Expectancy (Minimum Operations)

1 x 107

Electrical Life Expectancy (Minimum Operations)

1 x 105 at 30 Ampere (A) and 240 Alternating Current (AC) Voltage Respectively

Operate Time (Typical)

30 Millisecond (ms) Maximum at Nominal Coil Voltage

Release Time (Typical)

30 Millisecond (ms) at Nominal Coil Voltage (without Suppression)

Dielectric Strength at Sea Level for 1 Minute (min)

2200 Root Mean Square (RMS) Voltage (VRMS) Contact to Coil 2200 Root Mean Square (RMS) Voltage (VRMS) Contact to Contact

Insulation Resistance

100 Megaohm (MΩ) Minimum at 20 Degree Celsius (ºC) 500 Direct Current (DC) Voltage 50 Percent (%) RH

Direct Current (DC) Dropout

> 10 Percent (%) of Nominal Coil Voltage

Alternating Current (AC) Dropout

> 20 Percent (%) of Nominal Coil Voltage

Operating Ambient Temperature at Nominal Coil Voltage (Alternating Current (AC) Coil at 30 Ampere (A)

-45 to 85 ºC-49 to 176 ºF

Operating Ambient Temperature at Nominal Coil Voltage (Alternating Current (AC) Coil at 50 Ampere (A)

-45 to 70 ºC-49 to 239 ºF

Operating Ambient Temperature at Nominal Coil Voltage (Direct Current (DC) Coil at 30 Ampere (A))

-45 to 115 ºC-49 to 176 ºF

Operating Ambient Temperature at Nominal Coil Voltage (Direct Current (DC) Coil at 50 Ampere (A))

-45 to 105 ºC-49 to 239 ºF

Weight

227 g

Coil Specification

Power at Pickup Direct Current (DC) Voltage (Typical)

1.12 W

Maximum Continuous Power Dissipation Direct Current (DC) at 25 Degree Celsius (ºC) Temperature

3.3 W

Maximum Continuous Power Dissipation Alternating Current (AC) at 25 Degree Celsius (ºC) Temperature

12.5 V·A

Temperature Rise

70 ºC35 ºF

Maximum Temperature

155 ºC311 ºF

Nominal Coil Direct Current (DC) Voltage

24 V

Must Operate Direct Current (DC) Voltage

18 V

Maximum Continuous Direct Current (DC) Voltage

32 V

Nominal Current (±) 10 Percent (%)

83

Coil Resistance (±) 10 Percent (%)

11.5 290

Nominal Coil Alternating Current (AC) Voltage

24 V

Must Operate Alternating Current (AC) Voltage

20.4 V

Maximum Continuous Alternating Current (AC) Voltage

27.6 V

Nominal Coil Power

9.5 V·A

Features

Features

  • SPST, DPST, SPDT, and DPDT versions available
  • AC and DC coils available
  • UL Class F (155°C) molded construction
  • PRD, PRDD and PRDE are UL and cUL Listed
  • PRDS, PRDQ, and PRDR are UL cUR Recognized
  • UL, CUL file E44211

Note

Note

  1. All values at 25ºC (77ºF).
  2. Relay may pull in with less than "Must Operate" value.
  3. Specifications subject to change without notice
  • 1 24 V, 1 A voltage drop method